Application
Couplings are used for zero-loss transfer of liquid or gaseous media.
Execution
- Max. operating pressure 400 bar.
Notes
The coupling mechanism and coupling nipple must be inserted approx. 2-3 mm before the front-end sealing surfaces make contact. The radial positioning tolerance (+/- 0.2 mm) must not be exceeded. The couplings can only be coupled when unpressurised. The coupling force that occurs between the coupling nipple and the coupling mechanism due to hydraulic compression according to the formula F[N] = 15.4 x p [bar] must be taken into account.
Delivery
1x screw-in coupling nipple
Select RAL-colour code
!! NOTE: On-screen visualisation of the colour differs from real colour shade!!